Q2V
Driving quality - Q2V Compact Drive
The Q2 family offers a compact AC drive that combines easy operation with high-efficiency control for almost any motor type. The result is a robust product designed for maintenance free long-term operation.
- Hardware cost reduction: Built-in C1/C2/C3 class EMC filter and embedded functional safety (STO SIL3/PLe).
- Flexible motor control: IM, PM & SynRM motors.
- Customize your drive to your application by intuitive drag and drop programming.
- Save engineering and commissioning time thanks to software tools, mobile app and wizards.
- Proven robustness: Reduce machine downtime thanks to higher protection from dust and humidity.
Specifications & ordering info
Product | Drive control method | Drive supply voltage | Max. motor output at constant torque | Max. motor output at variable torque | Built in EMC filter | Degree of protection (IP) | Finless type | Compatible motor type | Regenerative solutions | Communication port(s) | Communication option(s) | Description | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Open loop V/f, Open loop vector | 230 V three phase | 0.25 kW | 0.37 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 1.9 A / 0.37 kW, HD: 1.6 A / 0.25 kW, with integrated EMC C3-Filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 0.55 kW | 0.75 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 3.5 A / 0.75 kW, HD: 3.0 A / 0.55 kW, with integrated EMC C3-Filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 0.75 kW | 1.1 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 6.0 A / 1.1 kW, HD: 5.0 A / 0.75 kW, with integrated EMC C3-Filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 0.75 kW | 1.1 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 6 A / 1.1 kW, HD: 5 A / 0.75 kW, without integrated EMC filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 1.5 kW | 2.2 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 9.6 A / 2.2 kW, HD: 8.0 A / 1.5 kW, with integrated EMC C3-Filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 2.2 kW | 3.0 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 12.2 A / 3 kW, HD: 11.0 A / 2.2 kW, with integrated EMC C3-Filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 4.0 kW | 5.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 21.0 A / 5.5 kW, HD: 17.6 A / 4 kW, with integrated EMC C3-Filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 4.0 kW | 5.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 21 A / 5.5 kW, HD: 17.6 A / 4 kW, without integrated EMC filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 5.5 kW | 7.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 30.0 A / 7.5 kW, HD: 25.0 A / 5.5 kW, with integrated EMC C3-Filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 7.5 kW | 11 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 42.0 A / 11.0 kW, HD: 33.0 A / 7.5 kW, with integrated EMC C3-Filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 11 kW | 15 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 56.0 A / 15.0 kW, HD: 47.0 A / 11.0 kW, with integrated EMC C3-Filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 15.0 kW | 18.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 70.0 A / 18.5 kW, HD: 60.0 A / 15.0 kW, with integrated EMC C3-Filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 15.0 kW | 18.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 70 A / 18.5 kW, HD: 60 A / 15 kW, without integrated EMC filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 230 V three phase | 18.5 kW | 22 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V 200V, ND: 82.0 A / 22.0 kW, HD: 75.0 A / 18.5 kW, with integrated EMC C3-Filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 0.37 kW | 0.37 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V, 400 V, ND: 1.2 A / 0.37 kW, HD: 1.2 A / 0.37 kW, IP20, EMC filter class C2, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 0.55 kW | 0.75 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V, 400 V, ND: 2.1 A / 0.75 kW, HD: 1.8 A / 0.55 kW, IP20, EMC filter class C2, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 0.55 kW | 0.75 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V, 400 V, ND: 2.1 A / 0.75 kW, HD: 1.8 A / 0.55 kW, IP20, without EMC filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 1.1 kW | 1.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V, 400 V, ND: 4.1 A / 1.5 kW, HD: 3.4 A / 1.1 kW, IP20, EMC filter class C2, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 1.1 kW | 1.5 kW | No | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V, 400 V, ND: 4.1 A / 1.5 kW, HD: 3.4 A / 1.1 kW, IP20, without EMC filter, max. output freq. 590Hz |
|
|
Open loop V/f, Open loop vector | 400 V three phase | 1.5 kW | 2.2 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2V, 400 V, ND: 5.4 A / 2.2 kW, HD: 4.8 A / 1.5 kW, IP20, EMC filter class C2, max. output freq. 590Hz |
|
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Contact Our Experts Q2V
Thank you for submitting your request. We will come back to you as soon as possible.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadQuotation for Q2V
By completing this form you can request a quotation. Your personal details will be handled confidentially.
Thank you for requesting a quotation. We will provide you with the required information as soon as possible.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadFeatures
Easy installation & setup
- Reduce cabinet size with side by side mounting without derating
- Screwless terminals safe wiring installation time
- Hardware simplification thanks to built-in EMC filter, safety STO and braking transistor
- 24 VDC power supply input for control board
- Intelligent application wizard for quick set up
- Mobile app for set up and monitoring
- Optional graphical LCD display with SD card for trace-recording
Application versatility
- Flexible motor control - IM, PM, SynRM
- V/f and Sensorless vector (current/voltage) motor control methods
- Speed and torque control in open loop
- Customized functions with application wizards
- Q2dev: Graphic development tool allows you to create your program
Proven robustness
- Coated PCB boards as standard protect the electronics from dust and humidity
- Designed for 10 years without maintenance
- Working operation up to 50 degrees without derating
- Experience matter: more than 10M drives installed
- CE, UL, cUL, RoHS
Q2app
Q2app
- Q2app allow you to connect to your Q2 series drives via Bluetooth or mini USB connection (only for Android devices).
- Q2A & Q2V inverters are supported.
- Drive status screen shows main indicators like motor speed, frequency reference, output frequency, output current, drive status, digital inputs and outputs status for a quick drive diagnosis.
- Any parameter can be changed and thanks to chart diagram visualization you can trace any parameter or monitor evolution over time.
- Hardware information can be checked as inverter family, model, serial number and firmware version, even if the ID label is not accessible.
Apple store Q2app
Scan to go directly to the Apple store to download the Q2app. Compatible with iPhone, iPad and iPod Touch.
Google Play store Q2app
Scan to go directly to the Google Play store to download the Q2app. Compatible with Android devices.