Login

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Register

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to content on this page

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Thank you for your interest

You now have access to CS Communication Units

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

CS Communication Units

CS Communication Units

Open to any communication, standard or user-defined

CS1 provides both standardised open networks interfaces, and cost-efficient high-speed proprietary network links. Datalinks between PLCs, or to higher-level information systems can be made using Serial or Ethernet links, or the easy-to-use Controller Link network.

Omron supports the 2 major field networks, DeviceNet and PROFIBUS-DP. For high-speed field I/O, Omron's own CompoBus/S offers an unsurpassed ease of installation. Fully user-configurable Serial and CAN-based communication can be used to emulate a variety of application-specific protocols.

Specifications & ordering info

Ordering information

Type

Ports

Protocols

Unit class

Remarks

Connection type

Order code

Serial

2 × RS-232C

CompoWay/F, Host Link, NT link, Modbus, User-defined

CPU bus unit

-

9-pin D-Sub

CS1W-SCU21-V1

Serial

2 × RS-422/RS-485

CompoWay/F, Host Link, NT link, Modbus, User-defined

CPU bus unit

-

9-pin D-Sub

CS1W-SCU31-V1

Serial

2 × RS-232C

CompoWay/F, Host Link, NT link, Modbus, User-defined

CPU option board

-

9-pin D-Sub

CS1W-SCB21-V1

Serial

1 × RS-232C +
1 × RS-422/RS-485

CompoWay/F, Host Link, NT link, Modbus, User-defined

CPU option board

-

9-pin D-Sub

CS1W-SCB41-V1

GP-IB

Master/Slave selectable

GP-IB instrument
communication

Special I/O unit

-

GP-IB

CS1W-GPI01

Ethernet

1 × 100 Base-Tx

UDP, TCP/IP, FTP server,
SMTP (e-mail), SNTP (time adjust),
FINS routing, socket service

CPU bus unit

-

RJ45

CS1W-ETN21

Controller link

2-wire twisted pair

Omron proprietary

CPU bus unit

-

2-wire screw + GND

CS1W-CLK23

Optical HPCF

-

2 × HPCF connector

CS1W-CLK13

Optical graded-index fiber

-

4 × ST connector

CS1W-CLK53

EtherNet/IP

1 × 100 Base-Tx

EtherNet/IP, UDP, TCP/IP, FTP server, SNTP, SNMP

CPU Bus unit

31 mm

RJ45

CS1W-EIP21

DeviceNet

1 × CAN

DeviceNet

CPU bus unit

-

5-p detachable

CS1W-DRM21-V1

CompoNet

4-wire, data + power to slaves (Master)

CompoNet (CIP-based)

Special I/O unit

-

4-p detachable IDC
or screw

CS1W-CRM21

CompoBus/S

2-wire (Master)

Omron proprietary

Special I/O unit

-

2-wire screw +
2-wire power

CS1W-SRM21

PROFIBUS-DP

1 × RS-485 (Master)

DP, DPV1

CPU bus unit

-

9-pin D-Sub

CS1W-PRM21

CAN

1 × CAN

CANopen, User-defined

CPU bus unit

-

5-p detachable

CS1W-CORT21

PROFINET IO

1 × 100 Base-Tx
PROFINET IO controller

FINS UDP

CPU bus unit

-

RJ45

CS1W-PNT21

PROFIBUS-DP

1 × RS-485 (Slave)

DP

C200H special
I/O unit

C200H units cannot be used on CS1D systems

9-pin D-Sub

C200HW-PRT21

Accessories

Description

Connection type

Order code

RS-232C to RS-422/RS-485 signal converter. Mounts directly on serial port.

9-pin D-sub to screw clamp terminals

CJ1W-CIF11

Controller link PCI board with support software

PCI, wired CLK

3G8F7-CLK23-E

Controller link PCI board with support software

PCI, HPCF connectors

3G8F7-CLK13-E

Controller link PCI board with support software

PCI, ST connectors

3G8F7-CLK53-E

Controller link repeater unit (wire to wire)

Screw - Screw

CS1W-RPT01

Controller link repeater unit (wire to HPCF fiber)

Screw - HPCF connector

CS1W-RPT02

Controller link repeater unit (wire to graded-index glass fiber)

Screw - ST connector

CS1W-RPT03

PROFIBUS DP to RS-422/RS-485 Serial Gateway. User-configurable, with Omron protocols built-in.

9-pin D-sub to screw clamp terminals

PRT1-SCU11

PROFINET IO + ModBus/TCP to Modbus/RTU (RS-485) Gateway.

3 × RJ45 to screw clamp terminals

EJ1N-HFU-ETN

Note: For Ethernet Cables and Accessories, see page

Accessories

Ethernet cables and accessories

EtherCAT patch cables, improved shield

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

20

30

50

100

150

200

300

500

750

1000

1500

2000

 

M12 straight

M12 straight

PVC

AWG22, 2 pairs

Black

XS5W-T421-[.]M2-SS

 

M12 straight

RJ45

PVC

AWG22, 2 pairs

Black

XS5W-T421-[.]MC-SS

Note: For [.] fill in the 1-character length code.

Ethernet patch cables, standard RJ45 connectors

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

20

30

50

100

150

200

300

500

750

1000

1500

2000

 

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Blue

XS6W-6LSZH8SS[...]CM-B

 

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Yellow

XS6W-6LSZH8SS[...]CM-Y

 

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Green

XS6W-6LSZH8SS[...]CM-G

 

RJ45 std.

RJ45 std.

PUR

Cat5e S/FTP 4 pairs

Green

XS6W-5PUR8SS[...]CM-G

Note: For [...] fill in the length in cm.

Ethernet patch cables, RJ45/M12 connectors

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

30

50

100

200

300

500

1000

1500

 

RJ45

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T421-[.]MD-K

 

M12 straight

M12 straight

PVC

Cat5e Shielded Quad

Light Blue

B

C

D

E

G

J

K

XS5W-T421-[.]M2-K

 

M12 straight

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T421-[.]MC-K

 

M12 angled

M12 angled

PVC

Cat5e Shielded Quad

Light Blue

B

C

D

E

G

J

K

XS5W-T422-[.]M2-K

 

M12 angled

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T422-[.]MC-K

Note: For [.] fill in the 1-character length code.

Specifications

Item

XS6W-6LSZH8SS_CM-_

XS6W-5PUR8SS_CM-G

Rated current

1 A (at 50°C)

Withstand voltage

1,000 VDC for 60 s (leakage current: 1 mA max.)

Ambient operating temperature

−20 to 60°C

−40 to 85°C

Ambient storage temperature

−20 to 60°C

−40 to 85°C

Ambient installation temperature

0 to 50°C

−10 to 60°C

Protective structure

IP20

IP20

Accessories

Ethernet cables and accessories

Accessories

Type

Connector

Specification

Color

Length

Order code

Ethernet installation cable

none

CAT 5, SF/UTP, 4 × 2 × AWG 24/1
(solid core), Polyurethane (PUR)

Green

100 m

WM IE-5IC4x2xAWG24/1-PUR

Ethernet installation cable

none

CAT 5, SF/UTP, 4 × 2 × AWG 26/7
(stranded core), Polyurethane (PUR)

100 m

WM IE-5CC4x2xAWG26/7-PUR

Ethernet socket

RJ45 socket

DIN-rail mount socket to terminate
installation cable in the cabinet

Grey

60 × 17.5 × 67 mm

WM IE-TO-RJ45-FJ-B

Ethernet field-mount plugs

Metal RJ45

for AWG22 to AWG26

Chrome

52 mm

WM IE-PS-RJ45-FH-BK

Ethernet field-mount plugs

Plastic RJ45

for AWG22 to AWG24

Black

52 mm

XS6G-T421-1

Industrial switching hubs

Shape

Functions

Ports

Failure detection

Power supply voltage

Order code

 

Quality of Service (QoS):

EtherNet/IP control data priority

Failure detection:

Broadcast storm and LSI error detection
10/100BASE-TX, Auto-negotiation

3

24.0 VDC±5%

W4S1-03B

 

5

W4S1-05B

W4S1-05C

EtherCAT junction slave

Shape

Functions

Ports

Power supply voltage

Order code

 

Creation of star- and tree topologies
in EtherCAT networks.

Distributed Clock (DC) is supported.

3

20.4 to 28.8 VDC

(24 VDC –15% to 20%)

GX-JC03

 

6

GX-JC06

 

How can we help you?

Want to know more about OMRON Industrial robots and robotics?

Request
Contact us

Contact me CS Communication Units

cs1-communit prod

Please, complete all the fields marked with *. Your personal details will be handled confidentially.

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Details

Text area error notification

Checkbox error notification

Checkbox error notification

Thank you for submitting your request. We will come back to you as soon as possible.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download
Request
Request
Request quotation
Request quotation

Quotation for CS Communication Units

By completing this form, you can request a quotation. Please note that only a company email address is accepted.

cs1-communit prod

Please, complete all the fields marked with *. Your personal details will be handled confidentially.

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Select notification error

Select notification error

Text area error notification

Checkbox error notification

Checkbox error notification

Thank you for requesting a quotation. We will provide you with the required information as soon as possible.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download
Request quotation
Request quotation

Downloads

download
CJ/CS-series EtherNet/IP EtherNet/IP EDS file
enZIP 5.94 KB
download
CS-series FL-net Units Operation Manual
enPDF 2.26 MB
download
CS/CJ-Series EtherNet/IP Units Operation Manual
enPDF 10.9 MB
download
CS-series FL-net Units Operation Manual
enPDF 2.26 MB
download
CS/CJ-Series EtherNet/IP Units Operation Manual
enPDF 10.9 MB